MDC1 Series Single Valve MDC1X27XNAEXMTA

  • Can achieve Category 1, PL c, when used with proper safety controls
  • The “fail-to-safe” safety function is ensured as long as the poppet is able to go back into the start position
  • Poppet Design that is dirt tolerant, wear compensating for quick response and high flow capacity
  • PTFE backup piston rings enhances valve endurance enabling operation with or without in-line lubrication
  • On energization, the Soft-Start (EEZ-ON®) allows outlet pressure to increase at a slower rate until it reaches approximately 50% of inlet pressure, at which point the valve will then open fully to finish filling the system at full rate
  • Threaded or modular port connection allows connection to Air Entry System (Lockout Valve, FRLs)
  • Threaded exhaust port for canister silencer or remote exhaust
  • SISTEMA Library available for download

Need Help? No Problem!

Technical & Customer Service

+44 (0)1254 872277

Need Help? No Problem!

Technical & Customer Service

+44 (0)1254 872277


Product Information

Series MDC
Valve Function 3/2 Single Solenoid
Construction Poppet
Actuation Electrical
Lockout Not Included
Monitoring External
Feedback Not Included
Reset Not Included
Exhaust Type Threaded Female Port
Thread Type NPT
Voltage 24 VDC
Mounting Inline/Modular
Ambient Temperature Range (Celcius) 4 to 50
Media Temperature Range (Celcius) 4 to 80
Flow Media Compressed Air
Valve Body Material Aluminum
Poppet/Spool Material Acetal and Stainless Steel
Seal Material Buna-N
Safety Category Category 1
PL Rating PL c
Safety Integrity Level SIL 1
DGUV Certification Pending
CE Certification Yes
EAC Declaration Yes
CSA/UL Certification Yes
Soft Start Not Included
Basic Size 1"
Exhaust Size 1-1/2"
Power Consumption 15 watts
Operating Pressure (bar) 2.5 to 10.3
Pressure Gauge Digital Transducer
Height (mm) 233.3
Length (mm) 130
Width (mm) 104.8
Weight (kg) 4.24
Solenoid Connection M12
Inlet Size 1-1/4"
Outlet Size 1-1/4"